Features : Built in µp based time interval meter measuring from 1 millisec to 9999 secs. Panel with easy & clear legends to read. Continuously variable outputs. Digital ammeter & voltmeter. Auto cut-off & output isolated. Self sensing of contacts i.e. NO or NC. Potential free start - stop signals. Fully portable , table top models with metal cover Primary current injection sets : | Model | Current Output AC | Metering | | AEP - 1 | 1000 A / 2 V | 500 A / 4V | 250A / 8V | | a) 3 1/2 Digit, Digital ammeter OR b) Analog ammeter with multiplying factor | | AEP - 2 | 1000 A / 5 V | 500 A / 10V | 250A / 20V | | | AEP - 3 | 2000 A / 2 V | 1000 A / 4V | 500A / 8V | 250 A /16 V | | AEP - 4 | 2000 A / 4V | 1000 A / 8V | 500A / 16V | 250 A /32 V | | AEP - 5 | 3000 A / 2 V | 1500 A / 4V | 750A / 8V | | | AEP - 6 | 4000 A / 2 V | 2000 A / 4V | 1000A / 8V | | | AEP - 7 | 5000 A / 2 V | 2500 A / 4V | 1250A / 8V | | Supply voltage : 230V AC +/- 10%,50 Hz. Indications : Main ON, Output ON, Output OFF. Operation : Contactor controlled push buttons for output ON/OFF. Duty cycled : 30 Min ON /15 min. OFF. Protection : a) Fuse / MCB . b) Over current protection. Termination : The outputs are brought out on the suitable bus bars. Secondary current injection sets / Relay test sets | Models | Current output AC, Variables | Optional voltage Output | | AC | DC | | AE -1 | 100A / 3 V | 75A / 4 V | 50A / 6V | 25A / 12V | 5A / 60V | 2A / 150V | 250 V / 2A | 250 V / 1.5A | | AE-2 | 200A / 4 V | 100A / 8 V | 50A / 16V | 25A / 32V | 10A / 80V | 5A / 160V | 250 V / 4A | 250 V / 1.5A | | AE-3 | 300A / 4 V | 200A / 6 V | 150A / 8V | 100A / 12V | 50A / 24V | 4A / 250V | 250 V / 4A | 250 V / 1.5A | | RTS 25 | 25A / 10 V | 5A / 50 V | - | - | | | 250 V / 1A | 250 V / 1A | | Supply voltage | : 230V AC +/- 10%,50 Hz. | | Metering | : a) 3 1/2 Digit digital Voltmeter b) 3 1/2 Digital percentage Ammeter c) 4 Digit µp based time interval meter 9.999 / 99.99 / 999.9 / 9999 secs. selectable. | | Timer Control Circuit | : The timer automatically starts when the output is initiated and automatically stops when the device under test operates. | | Test Conditions | : a) Current activated device without auxiliary contacts. b) NO contacts. c) NC contacts. | | Auto cut-off | : Cuts off output on operation of item under test. | | Operation | : Contactor controlled push buttons for output ON/OFF. | | Duty cylced | : 120Min ON / 30 min. OFF. | | Indications | : Main ON, Output ON, Output OFF. | | Protection | : a) Fuse / MCB . b) Over current protection. | |